Utility Package (Gx Configurator-Sc) Function List - Mitsubishi Electric QJ71C24N User Manual

Q corresponding serial communication module
Table of Contents

Advertisement

3
SPECIFICATIONS

3.6 Utility Package (GX Configurator-SC) Function List

Refresh the Q series C24's error codes and set devices on the
Auto refresh setting
programmable controller CPU side.
User frame
Register the user frame in the flash ROM.
Data for modem initialization Register the data for modem initialization in the flash ROM.
Data for modem connection
Register the data for model connection in the flash ROM.
Modem function system
Register the system setting values for model function in the flash
setting
ROM.
CHn Transmission
Set the transmission specifications with the other device.
control and others
(DTR/DSR control, DC code control, communication method, data
system setting
communication monitoring timer value, etc.)
CHn MC protocol
Assign the buffer memory for on-demand function, set the user
system setting
frame number, etc.
Assign the buffer memory needed to perform data communication
CHn Non procedure
using the non procedure protocol, and change the setting values,
system setting
etc.
CHn Bidirectional
Assign the buffer memory needed to perform data communication
System
system setting
using the bidirectional protocol, and change the setting values, etc.
setting
CHn Pre-defined
Change the set values for data communication by the pre-defined
protocol system
protocol.
setting
CHn PLC CPU
monitoring system
Set the programmable controller CPU monitoring function.
setting
CHn Transmission
user frame No.
Set the user frame number to be transmitted, etc.
designation system
setting
Reset the setting values in the buffer memory to their default
System setting default
values.
System setting write
Write the setting values in the buffer memory to the flash ROM.
Flash ROM write
Set whether to allow or prohibit writing to the flash ROM.
allow/prohibit designation
Perform the monitoring/testing of I/O signals to/from the
X/Y monitor/test
programmable controller CPU.
Modem function monitor/test Monitor the execution status of the modem function.
CHn Transmission
Monitor the status of interface control signals, values set from the
control and others
GX Developer, etc.
monitor/test
CHn MC protocol
monitor
CHn Non procedure
Monitor the data communication result, I/O signal status, and
monitor/test
setting values in the buffer memory.
CHn Bidirectional
monitor
Monitor
CHn Pre-defined
Monitor the data communication result, I/O signal status, and
protocol
setting values in the buffer memory.
monitor/test
CHn PLC CPU
Monitor the setting values and operating status of the
monitoring monitor
programmable controller CPU monitoring function.
CHn User frame
No. designation
Monitor the setting value for user frame to be transmitted.
monitor for
transmission
Monitor/test others
Monitor the data reception result, error occurrence status, etc.
ERR LED off
Turn off the ERR LEDs on the front face of the module.
3 - 17
The following table lists the utility package function for the Q series C24.
Function
(
: Protocol for which setting is valid)
Protocol
Explanation
MC
Non
Bi
Pd
Section 4.6
Section 9.4.1
Section 9.4.2
Section 9.4.3
Section 9.4.4
Section 9.4.5
Section 9.4.6
Section 9.4.7
Section 9.4.8
Section 9.4.9
Section 9.4.10
Section 9.4.11
Section 9.4.12
Section 9.4.12
Section 9.4.13
Section 9.6.1
Section 9.6.2
Section 9.6.3
Section 9.6.4
Section 9.6.5
Section 9.6.6
Section 9.6.7
Section 9.6.8
Section 9.6.9
Section 9.6.10
Section 9.6.11
MELSEC-Q
Remarks
page
Can be used
via online
operation.
Can be used
via offline
operation.
Can be used
only via
online
operation.
3 - 17