3
SPECIFICATIONS
Address
Decimal (Hex)
Application
CH1
CH2
Programmable
controller CPU
8711
8967
monitoring
(2207
)
(2307
)
H
H
function
8712 to
8968 to
8943
9215
(2208
(2308
Use prohibited
H
H
to
to
22EF
)
23FF
)
H
H
8944 (22F0
)
H
8945 (22F1
)
H
For callback
8946 (22F2
)
H
function
8947 (22F3
)
H
8948 (22F4
)
H
8949 to 8954
Use prohibited
(22F5
to 22FA
)
H
H
8955 (22FB
)
H
For the remote
password
function
8956(22FC
)
H
8957 to 8958
Use prohibited
(22FD
to 22FE
)
H
H
For the remote
password
8959(22FF
)
H
function
9216(2400
)
Use prohibited
H
For flash ROM
9217(2401
)
write count
H
housing
9218 to 9427
Use prohibited
(2402
to 25FF
)
H
H
9728 to 16383
For user
(2600
to 3FFF
)
H
H
16384
16416
to
to
16415
16447
Use prohibited
(4000
(4020
H
H
to
to
401F
)
403F
)
H
H
Pre-defined
protocol function
16448
16464
(4040
)
(4050
)
control data
H
H
specification
3 - 36
Name
Monitoring condition arrival block No.
0
: The monitoring condition is not enabled for any block
1 to 10: Registration order of word/bit block (nth)
4096 : CPU abnormal monitoring block
The latest block No. for which monitoring condition is enabled is
stored.
System area
Callback permit accumulated count
0 or more: Accumulated count
Callback denial accumulated count
0 or more: Accumulated count
Auto (callback) connection permit accumulated count
0 or more: Accumulated count
Auto (callback) connection denial accumulated count
0 or more: Accumulated count
Accumulated count of callback receive procedure cancel
0 or more: Accumulated count
System area
Accumulated count of unlock process normal completion
0 or more: Accumulated count of normal completion
Accumulated count of unlock process abnormal completion
processing
0 or more: Accumulated count of abnormal completion
System area
Accumulated count of lock process based on circuit disconnection
0 or more: Accumulated count of lock process based on circuit
disconnection
System area
Flash ROM write count
0 to 1000: Write count
System area
User free area 2 (6656 words)
(Transmission/receiving data monitoring function default buffer)
Usage is determined by the user.
System area
Protocol cancel
0: No cancel instruction
1: Cancel request (set by user)
2: Cancel completed (set by Q series C24N)
MELSEC-Q
Protocol
Initial
Registration
value
MC Non Bi Pd
0
R
—
Not allowed
—
—
0
RW
Not allowed
—
—
0
RW
Not allowed
—
—
0
RW
Not allowed
—
0
R
Not allowed
—
0
RW
Not allowed
—
—
0
RW Not allowed
Reference
section
User's Manual
(Application)
Section 9.6.2
User's Manual
(Application)
Section 5.1.5
Section 9.6.2
User's Manual
(Application)
Section 5.1.5
Section 9.6.2
User's Manual
(Application)
—
—
Section 8.1.3,
Operating
Manual
(Pre-defined
protocol
support
function)
3 - 36