5 UTILITY PACKAGE (GX Configurator-TC)

5 UTILITY PACKAGE (GX Configurator-TC)

5.1 Functions of the Utility Package

Function
5
Initial setting
5 - 1
Downloaded from
ManualsNet.com
Table 5.1 lists the functions of the utility package.
Table 5.1 Utility package (GX Configurator-TC) function list
(1) Make initial setting for operating the temperature control module channel-by-channel.
Set the values of the items which require initial setting.
• CH
Input Range
• CH
Set Value (SV) Setting
• CH
Proportional Band (P) Setting
• CH
Integral Time(I) Setting
• CH
Derivative Time(D) Setting
• CH
Control Output Period Setting
• CH
Control Response Parameter
• CH
Stop Mode Setting
• PID Continuation Flag
• CH
Alert 1 Mode Setting
• CH
Alert Set Value1
• CH
Alert 2 Mode Setting
• CH
Alert Set Value2
• CH
Alert 3 Mode Setting
• CH
Alert Set Value3
• CH
Alert 4 Mode Setting
• CH
Alert Set Value4
• Alert Dead Band Setting
• Alert Delay Count
• CH
Loop Disconnection Detection
Judgment Time
• CH
Loop Disconnection Detection Dead
Band
• CH
Heater Disconnection Alert Setting
• Heater Disconnection/Output Off-time
Current Error Detection Delay Count
(2) The initially set data are registered to the programmable controller CPU parameters, and when
the programmable controller CPU is set to the RUN mode, they are written to the temperature
control module automatically.
search engine
Description
• Heater Disconnection Compensation
Function Selection
• CT Monitor Method Switching
• CT
Channel Assignment Setting
• CT
CT Selection
• CT
Reference Heater Current Value
• CH
Upper Setting Limiter
• CH
Lower Setting Limiter
• CH
Forward/Reverse Action Setting
• CH
Setting Change Rate Limiter
• CH
Sensor Compensation Value Setting
• CH
Primary Delay Digital Filter Setting
• CH
Upper Output Limiter
• CH
Lower Output Limiter
• CH
Output Variation Limiter
• CH
Adjustment Sensitivity (Dead Band)
Setting
• CH
AT Bias
• CH
Auto Tuning Mode Selection
• CH
Unused Channel Setting
• Transistor Output Monitor ON Delay Time
Setting
• Manipulated Value Resolution Switching
• Temperature Rise Completion Range
Setting
• Temperature Rise Completion Soak Time
Setting
MELSEC-Q
Reference
section