PROFINET Module Settings (Starting GX
Configurator-PN)
Start GX Configurator-PN to set PROFINET communication parameters.
[Navigation window]  [Parameter]  [Module Information]  [RJ71PN92]  [PROFINET Module Setting]
For details, refer to the following.
Page 63 GX Configurator-PN
While GX Configurator-PN is running, another GX Configurator-PN cannot be started.
Verifying the PROFINET module setting
Verify the project data set in GX Configurator-PN and the parameter written to the RJ71PN92.
[Navigation window]  [Parameter]  [Module Information]  [RJ71PN92]  Right-click  [Verify Configuration]
When the verification is completed, the result is displayed in the dialog window.
2 PARAMETER SETTINGS
54

2.3 PROFINET Module Settings (Starting GX Configurator-PN)