Mitsubishi Electric QJ71C24N User Manual page 95

Q corresponding serial communication module
Table of Contents

Advertisement

3
SPECIFICATIONS
Address
Decimal (Hex)
Application
CH1
CH2
8256
8512
(2040
)
(2140
)
H
H
8257
8513
(2041
)
(2141
)
H
H
8258
8514
(2042
)
(2142
)
H
H
8259
8515
(2043
)
(2143
)
H
H
For designation
of programmable
controller CPU
monitoring
8260
8516
function
(2044
)
(2144
)
H
H
8261
8517
(2045
)
(2145
)
H
H
8262
8518
(2046
)
(2146
)
H
H
8263 to
8519 to
8268
8524
(2047
(2147
Use prohibited
H
H
to
to
204C
)
2149
)
H
H
8269
8225
(204D
)
(214D
)
H
H
8270
8226
(204E
)
(214E
)
H
H
8271
8527
(204F
)
(214F
)
H
H
8272
8528
(2050
)
(2150
)
H
H
8273 to
8529 to
8274
8530
(2051
(2151
H
H
to
to
2052
)
2152
)
H
H
8275
8531
(2053
)
(2153
)
H
H
For designation
8276
8532
(2054
)
(2154
)
of programmable
H
H
controller CPU
monitoring
8277
8533
function
(2055
)
(2155
)
H
H
8278
8534
(2056
)
(2156
)
H
H
8279
8535
(2057
)
(2157
)
H
H
8280
8536
(2058
)
(2158
)
H
H
3 - 34
Name
Cycle time units designation
0: 100 ms
1: s
Cycle time designation
0
: No designation
H
1
to FFFF
: Programmable controller CPU monitoring cycle time
H
H
Programmable controller CPU monitoring function designation
0: Do not use the function.
2: Condition agreement transmission
Programmable controller CPU monitoring transmission measure
designation
0: Data transmission (device data and CPU status data)
1: Notification
Transmission pointer designation (For fixed cycle transmission and
non-procedure data transmission)
0: No designation
1 to 100: Output head point (send from the nth)
Send the user frames designated in the following transmission
frame No. designation areas from the designated pointer
position.
(addresses: CH1 side = BA
H
1BD
)
H
Output count designation (for fixed cycle transmission and non-
procedure data transmission)
0: No designation
1 to 100: Output count (designate the number of frame
transmissions.)
Data No. for connection designation (for fixed cycle transmission
and notification)
0: No designation
0BB8
to 0BD5
, 8001
to 801F
H
H
H
System area
Number of registered word blocks designation
0
: No designation
1 to 10: Number of blocks of word devices
Number of registered bit blocks designation
0
: No designation
1 to 10: Number of blocks of bit devices
Programmable controller
CPU abnormal monitoring designation
0: Do not monitor.
Monitoring device designation
0: No designation
90
to CC
: Device code
H
H
Head device No. designation
0 or more: Head device No.
Read point designation
0: No designation
1 or more: Number to read points
Monitoring condition designation (judgment condition
designation)
0: No designation
1 or more: Monitoring condition
Monitoring condition value designation
At bit device
0: OFF 1: ON
No. 1
At word device 0 to FFFF
block
value
monitoring
Transmission pointer designation (for condition
device
agreement transmission and non-procedure data
transmission)
0: No designation
1 to 100: Output head point (send from nth)
Send the user frames designated in the following
transmission frame No. designation areas from the
designated pointer position.
(address: CH1 side = BAH to 11DH, CH2 side = 15AH
to 1BDH)
Output count designation (for condition agreement
transmission and non-procedure data transmission)
1 to 100: Output count (designate the number
of frame transmissions)
Data No. for connection designation (for condition
agreement transmission and notification)
0BB8
to 0BD5
, 8001
H
H
2: min
1: Fixed cycle transmission
to 11D
, CH2 side = 15A
to
H
H
: Data No. for connection
H
It is possible to
designate a
maximum of 10
blocks in total.
1: Monitor.
: Monitoring condition
H
to 801F
: Data No. for
H
H
connection
MELSEC-Q
Initial
Protocol
Registration
value
MC Non Bi Pd
2
5
H
R
0
Allowed
0
R
R
R
0
Allowed
R
R
Reference
section
User's Manual
(Application)
User's Manual
(Application)
3 - 34

Advertisement

Table of Contents
loading