DEFINITIONS AND DESCRIPTIONS OF TERMINOLOGY

The following table lists the definitions and descriptions of terminology used in this manual and related
manuals for the Q series serial communication modules.
Terms
A compatible 1C frame
(Formats 1 to 4)
Bidirectional protocol
Independent operation
GX Configurator-SC
GX Developer
GX Works2
Linked operation
MX Component
MELSEC communication protocol
(MC protocol)
Message send function
(Printer function)
Multidrop connection
Non procedure protocol
Packet
Pre-defined protocol
Pre-defined protocol support function
A - 22
One of the message formats for the serial communication module for performing communication
using the MC protocol and ASCII code data.
This is the same message format as when communicating using the protocol for the A series
computer link modules. Device memory read/write operations for the QCPU are allowed within
the device range of the AnACPU.
A communication procedure for the serial communication modules and one of the data
communication functions for communicating any data between the programmable controller CPU
and an opposite device.
A mode of interface operation to communicate data with external devices using a function
specified in each communication protocol setting. Two interfaces of serial communication
modules do not interact.
Setting and monitoring tool for the serial communication module (MELSOFT product)
The product name of the software package for the MELSEC programmable controllers
The operation mode of each of the two interfaces for a serial communication module that are
connected to external devices and linked to one another in order to send/receive data to/from the
external devices.
The two interfaces communicate data using the identical data-communication function (MC
protocol (identical format) or non procedure protocol) and the identical transmission
specifications. (Linked operation using the bidirectional or pre-defined protocol is not allowed.)
®
Active X
control library for serial communication (MELSOFT product)
A communication procedure for the Q series serial communication modules or the Ethernet
interface modules, and a name of communication method for accessing to the programmable
controller CPU from an opposite device. (This is called the MC protocol in this manual.)
There are two communication methods; one uses ASCII code data and the other uses binary
code data.
This function registers character data (messages) to be sent to external devices (mainly printers)
in the serial communication module as a user frame in advance, and sends the registered data
for multiple user frames using the non-procedure protocol (sent by an instruction from the
programmable controller CPU).
A name of the connection when multiple external devices or other serial communication modules are
connected in a 1:n or m:n mode using the serial communication module's RS-422/485 interface.
A user's communication procedure and one of the data communication functions for
communicating any data between the programmable controller CPU and an opposite device.
A string of data used for communication with external devices by the pre-defined protocol.
One of the data communication functions available for the QJ71C24N(-R2/R4).
In data communication between the QJ71C24N(-R2/R4) and an external device, data can be
sent and received by using a protocol for the external device.
This must be set in GX Configurator-SC (Pre-defined protocol support function).
A function available in GX Configurator-SC (Pre-defined protocol support function), which
includes:
• Registration of the protocol appropriate to each external device
• Writing protocol setting data to or reading them from the flash ROM of the QJ71C24N(-R2/R4)
• Debug support function
Description
A - 22