6
DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL
Q series C24 ready (X1E)
Transmission instruction
OUTPUT instruction
OUTPUT instruction complete device
OUTPUT instruction complete device + 1
(normal completion/abnormal
completion)
Transmission data count
designation (address: 400
H
Transmission data
designation (address: 401
H
6 - 28
1)
2)
3)
)
to)
Transmitting data
1) Starts the local station programmable controller CPU.
The setting values for GX Developer are stored in the Q series C24.
2) Inputs the user data transmission command signal.
3) Executes the OUTPUT instruction after storing the transmission data and the
control data for the OUTPUT instruction in the device.
Data is sent when the OUTPUT instruction is executed.
4) When the Q series C24 transmission processing completes, the completion device
for the OUTPUT instruction turns ON.
When the completion device + 1 (abnormal completion signal) turns ON, the error
code is stored in the control data completion status (S1+1).
OUTPUT
4)
0
MELSEC-Q
ON when transmission
abnormal completion
1 scan
n
Transmission data
6 - 28