FAULT CODE
Rollover sensor - signal line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The rollover sensor is disconnected.
Rollover sensor - check the signal line for an open circuit
Measure the resistance between the specified points.
Break Out Box DT Pin 2 – Connector AP Pin 5
Resistance
»
If the measured value does not correspond to the specified value:
Check connector DT pin 2 and connector AP pin 5.
Check the cable from connector DT pin 25 to connector AP pin 5 for an open circuit.
»
If the measured value corresponds to the specified value:
Check the next possible cause:
Rollover sensor - ground line is open (
Rollover sensor - ground line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The rollover sensor is disconnected.
Rollover sensor - check the ground line for an open circuit
Measure the resistance between the specified points.
Break Out Box DT Pin 24 – Connector AP Pin 4
Resistance
»
If the measured value does not correspond to the specified value:
Check connector DT pin 24 and connector AP pin 4.
Check the cable from connector DT pin 24 to connector AP pin 4 for an open circuit.
»
If the measured value corresponds to the specified value:
Contact customer service.
600849-01
p. 218)
600849-01
400583-10
≤ 0.6 Ω
400583-10
≤ 0.6 Ω