Assembling The Compression Damping Fitting - HUSABERG FE 450 EU Repair Manual

2009 year
Hide thumbs Also See for FE 450 EU:
Table of Contents

Advertisement

01/FORK, TRIPLE CLAMP

Assembling the compression damping fitting

5.17
Info
The steps are identical for both fork legs.
Measure the run-out of the inner tube.
Inner tub run-out
»
If the measured value is larger than the specified value:
Replace the inner tube.
200685-10
Check the outer tube for damage.
»
If there is damage:
Replace the outer tube.
200632-10
Check the surface of the sliding bushing.
»
If the bronze-colored layer
Replace the sliding bushing.
200665-10
Check the spring length.
Guideline
Spring length with preload spacer(s)
»
If the measured value is greater than the specified value:
Reduce the thickness of the preload spacer.
»
If the measured value is smaller than the specified value:
Increase the thickness of the preload spacer.
200666-10
Clamp the compression damping fitting in a bench vise using soft jaws.
Mount O-ring
Grease the O-ring.
Lubricant (T158) (
200704-11
can be seen beneath the sliding layer
and seal ring
.
p. 265)
≤ 0.20 mm (≤ 0.0079 in)
510 mm (20.08 in)
20
:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fe 570 euFe 570 usaFe 450 usaFe 570 ausFe 450 aus