FAULT CODE
»
If the measured value corresponds to the specified value:
Check the next possible cause:
Fuel pump - power supply is faulty (
Fuel pump - power supply is faulty
Condition
The diagnostic tool is connected and active.
The breakout box is connected to the EFI control unit and wiring harness.
Fuel pump - check the power supply
Measure the voltage between the specified points.
Break Out Box DT Pin 14 – measuring point Ground(−)
Info
For the measurement, the measurement points must be loaded with a 12V/21W bulb.
The value should not vary more than 1V from the battery voltage "VBAT".
»
If the measured value does not correspond to the specified value:
Check the cable from the connector of fuse pin 2 to connector DT pin 14 for an open circuit.
»
If the measured value corresponds to the specified value:
Contact customer service.
p. 212)
600849-01
400607-11
212