FAULT CODE
Ignition coil - check the control line for a short circuit to plus (terminal 30)
Measure the voltage between the specified points.
Break Out Box DT Pin 18 – measuring point Ground(−)
Voltage
»
If the measured value does not correspond to the specified value:
Check the cable from connector DT pin 18 to pin 1 of the ignition coil for a short circuit to plus (terminal 30).
»
If the measured value corresponds to the specified value:
Check the next possible cause:
Ignition coil - control line has a short circuit to ignition plus (terminal 15) (
Ignition coil - control line has a short circuit to ignition plus (terminal 15)
Ignition coil - control line is open
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The control line of the ignition coil is disconnected.
Connect battery plus with Break Out Box PIN 18.
Info
The connection must be protected with a 5A fuse.
600849-01
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The control line of the ignition coil is disconnected.
Ignition coil - check the control line for a short circuit to ignition plus (terminal 15)
Measure the resistance between the specified points.
Break Out Box DT Pin 1 – Break Out Box DT Pin 18
Resistance
»
If the measured value does not correspond to the specified value:
Check the cable from connector DT pin 18 to pin 1 of the ignition coil for a
short circuit to ignition plus (terminal 15).
»
If the measured value corresponds to the specified value:
600849-01
Check the next possible cause:
Ignition coil - control line is open (
400607-11
< 0.1 V
p. 206)
∞ Ω
p. 206)
206