HUSABERG FE 450 EU Repair Manual page 201

2009 year
Hide thumbs Also See for FE 450 EU:
Table of Contents

Advertisement

FAULT CODE
Flash code FI warning
lamp (MIL)
Display on diagnostic tool
Error level condition
Function check
Possible cause
Ignition pulse generator - checking the signal
Condition
The diagnostic tool is connected and active.
Select the model type.
Select "ECU Diagnostic".
Highlight the "Engine electronics EXC" control unit.
Press "Continue".
Select "Measurement values".
Highlight "Starter".
Press "Continue".
Highlight the measured value "Engine speed (NE)" and deselect the other parameters with "Select measured value".
Perform the starting procedure.
"Engine speed (NE)"
»
If the specification is attained:
Delete the fault code.
Make a test ride.
Read out the fault code.
»
If the specification is not attained:
Check the next possible cause:
Ignition pulse generator - value not plausible (
Ignition pulse generator - value not plausible
02 FI warning lamp (MIL) flashes 2x short
P0335
"Circuit ignition pulse generator"
"Malfunction in the circuit"
The manifold absolute pressure sensor is generating a standard signal (the engine is running),
whereas the ignition pulse generator is not generating any signal.
The engine will be switched off: ≥ 1 s
Ignition pulse generator - checking the signal (
Ignition pulse generator - value not plausible (
Ignition pulse generator - signal lines are open (
Ignition pulse generator - signal lines have a short circuit to each other (
Ignition pulse generator - signal lines have a short circuit to ground (terminal 31) (
Ignition pulse generator - signal lines have a short circuit to sensor ground (
Ignition pulse generator - signal lines have a short circuit to plus (terminal 30) (
Ignition pulse generator - signal lines have a short circuit to ignition plus (terminal 15)
(
p. 202)
Ignition pulse generator - signal line has a short circuit to the sensor power supply (
p. 199)
Condition
Ignition pulse generator is disconnected.
Ignition pulse generator - check the resistance
Measure the resistance between the specified points.
Connector AT Pin 1 – Connector AT Pin 2
Pulse generator
Resistance at: 20 °C (68 °F)
»
If the measured value does not correspond to the specified value:
Change the ignition pulse generator.
»
If the measured value corresponds to the specified value:
400585-10
Check the next possible cause:
Ignition pulse generator - signal lines are open (
p. 199)
p. 199)
p. 200)
Starter speed
80... 120 Ω
199
p. 200)
p. 200)
p. 201)
p. 201)
p. 202)
p. 200)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fe 570 euFe 570 usaFe 450 usaFe 570 ausFe 450 aus