30/ENGINE ASSEMBLY
Adjusting the valve clearance
20.36
Installing the generator cover
20.37
–
Check the valve clearance at all valves between the valve and rocker arm.
Guideline
Valve clearance
Exhaust at: 20 °C (68 °F)
Intake at: 20 °C (68 °F)
Feeler gauge (59029041100) (
300518-10
»
If the valve clearance does not meet specifications:
–
Adjust the valve clearance. (
–
Mount and tighten screw
Guideline
Plug, crank shaft location with thick
copper disk
300299-11
–
Remove the timing chain tensioner. (
–
Remove the camshaft. (
–
Raise rocker arm
–
Remove shims
–
Correct the shims according to the findings from checking the valve play.
–
Insert the fitting shims
–
Install the camshaft. (
–
Install the timing chain tensioner. (
–
Check the valve clearance. (
300524-10
–
Mount centering pins
300361-10
–
Position the generator cover. Mount screws
cover screws have been mounted.
Guideline
Screw, generator cover
–
Mount screws
mounted.
Guideline
Screw, generator cover
300297-12
–
Mount screw
Guideline
Screw, generator cover
(chain shaft through-hole)
p. 269)
p. 149)
.
p. 101)
p. 101)
on the outside.
and set down in the position in which they were installed.
.
p. 148)
p. 148)
p. 148)
. Position the generator cover seal.
and tighten once all of the generator cover screws have been
with the seal ring and tighten all screws in a crisscross pattern.
M6x30
0.12... 0.17 mm (0.0047...
0.0067 in)
0.10... 0.15 mm (0.0039...
0.0059 in)
M8
10 Nm (7.4 lbf ft)
and tighten once all of the generator
M6x30
10 Nm (7.4 lbf ft)
M6x50
10 Nm (7.4 lbf ft)
10 Nm
Loctite
®
(7.4 lbf ft)
149
243™