Reference
Information
This section provides information about:

Included Parts

Because the DFX 100 Tx and DFX 100 Rx are compatible with other Extron products, they
are sold as individual units.

Mounting

Desktop Placement

Attach the four provided rubber feet to the bottom of the DFX 100 transmitter or receiver
and place the unit in any convenient location.

Rack Mounting

UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of
these products in a rack:
Elevated operating ambient temperature — If the units are installed in a closed or multi-
unit rack assembly, the operating ambient temperature of the rack environment may be
greater than room ambient temperature. Therefore, install the equipment in an environment
compatible with the maximum ambient temperature (Tma: +122 °F, +50 °C) specified by
Extron.
Reduced air flow — Install the equipment in the rack so that the equipment gets adequate
air flow for safe operation.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
Circuit overloading — Connect the equipment to the supply circuit and consider the effect
that circuit overloading might have on overcurrent protection and supply wiring. Consider
the equipment nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment.
Pay particular attention to supply connections other than direct connections to the branch
circuit (such as the use of power strips).
Included Parts
Mounting
DFX 100 • Reference Information