Monitor/Test Mode [User-Registered Devices]; Monitor Mode Operation - Mitsubishi FX3U SERIES User Manual

Hide thumbs Also See for FX3U SERIES:
Table of Contents

Advertisement

FX
Series Programmable Controllers
3U
User's Manual - Hardware Edition
19.8

Monitor/Test Mode [User-Registered Devices]

Regarding user-registered devices at "Monitor/Test" menu, monitor and test operations can be performed for
a maximum of 4 data registers (16-bit/32-bit) specified by the system information.

19.8.1 Monitor mode operation

1) At the menu screen, use the [+] and [-] buttons to move the cursor
to the "Monitor/Test" item, then press [OK] to display the "device
selection screen" shown to the right.
To cancel the operation and return to the "top screen (time
display)", press [ESC] at the menu screen
2) "Use the [+] and [-] buttons to move the cursor to the "User" item.
To cancel the operation and return to the "device selection screen",
press [ESC].
3) Press [OK] to display the data registers specified by the system
information.
The first time the power is turned on, the display begins with device
No.1 of the "user-registered devices". At subsequent power ONs,
the device which was being monitored at the previous operation is
displayed.
If a specified user-registered device has been changed, the newly
specified device is displayed.
To cancel the operation and return to the "device selection screen", press [ESC].
Device comments (registered at the PLC) are displayed together with the devices.
[1]
If no device comment has been registered, the device comment area is left blank.
[2]
Device included in the user-registered devices
[3]
Current value
4) Use the [+] and [-] buttons to scroll the user-registered devices
screen.
To cancel the operation and return to the "device selection screen",
press [ESC].
Button
ESC
-
+
OK
→ Refer to Section 19.19 for the user-registered device setting procedure.
Returns to the "device selection screen".
Scrolls the user-registered devices.
(User-specified device 1 → user-specified device 4 → user-specified device 3 → user-specified
device 2 → user-specified device 1)
Scrolls the user-registered devices.
(User-specified device 1 → user-specified device 2 → user-specified device 3 → user-specified
device 4 → user-specified device 1)
Switches to the test mode when hold for 1 second or longer.
19.8 Monitor/Test Mode [User-Registered Devices]
D ( 1 6 b i
D D ( 3 2
T
C
R ( 1 6 b i
D R ( 3 2
E R ( 1 6 b i t )
D
X
Y
M
S
U s e r
H a l t
D 1 0 0
Display Content
D 1 0 3
Operation Description
19 FX3U-7DM (Display Module)
t )
b i t )
t )
b i t )
E R ( 3 2 b i t )
t i m e r
[1]
[2]
1 0
[3]
D 1 0 4
0
365
11
12
13
14
15
16
17
18
19
20