2. Main unit + input/output powered extension unit/block
Example of program
M8000
Examples of wiring
In the case of sink wiring
When the main unit and a transistor output (sink) type input/output powered extension unit/block are used
S/S
*1 To use the input terminal (X) of the input/output powered extension unit, wire the terminal as shown by the dotted line.
*2 The terminals in the shaded areas are provided on input/output powered extension units (ex.: FX
Output extension blocks do not have the terminals.
In the case of source wiring
When the main unit and a transistor output (source) type input/output powered extension unit/block are used
S/S
*1 To use the input terminal (X) of the input/output powered extension unit, wire the terminal as shown by the dotted line.
*2 The terminals in the shaded areas are provided on input/output powered extension units (ex.: FX
Output extension blocks do not have the terminals.
226
DSW
X010
Y050
10
0
Digital
switch of
BCD
0.1A 50V
diode is
necessary.
1
2
0V
24V
X010 X011 X012 X013
Main unit
Digital
10
0
switch of
BCD
0.1A 50V
diode is
necessary.
1
2
0V
24V
X010 X011 X012 X013
Main unit
13.2 Digital Switch [DSW Instructions (FNC72)/BIN Instructions (FNC19)]
D100
K1
10
1
10
2
*1
4
8
COM
24+
Input/output powered extension unit
Output extension block
Transistor output (sink)
COM1
Y050 Y051 Y052 Y053
10
10
1
10
2
*1
4
8
S/S
0V
Input/output powered extension unit
Output extension block
Transistor output (source)
+V0
Y050 Y051 Y052 Y053
10
13 Examples of Wiring for Various Uses
10
3
*2
X
0
10
1
10
2
10
3
2N
10
3
*2
24V
X
0
10
1
10
2
10
3
-32ET-ESS/UL).
2N
-32ET).