Data register
(32 bits when
paired)
Extension register (16 bits)
Extension file register (16 bits)
Pointer
Nesting
Constant
Operating frequency of high-speed counter
For hardware and software counter device numbers, refer to the following section.
Kind of high-speed counter
Hardware counter
Software counter
Item
For general (16 bits)
D0 to D199
[changeable]
For keeping (16 bits)
D200 to D511
[changeable]
For keeping (16 bits)
D512 to D7999
[fixed]
<D1000 to
<File register>
For special (16 bits)
D8000 to D8511
For index (16 bits)
R0 to R32767
For branching of
P0 to P4095
JAMP and CALL
Input interruption and
input delay
I0
interruption
Timer interruption
I6
Counter interruption
I010 to I060
For master control
Decimal number (K)
Hexadecimal number
(H)
Real number (E)
Character string (" ")
Character string
Input terminals (X000 to X007)
of main unit
1-phase 100 kHz x 6 points, 10 kHz x 2 points
50 kHz (multiply by 1),
2-phase
50 kHz (multiply by 4)
1-phase 40 kHz
40 kHz (multiply by 1),
2-phase
10 kHz (multiply by 4)
4 Specifications, External Dimensions and Terminal Layout (Main Units)
Performance
200 points
The retentive status can be changed by
parameter settings.
312 points
D1000 and later in 7488 points of fixed
7488 points
data register for keeping can be set as
<7000
file register points in 500-point units by
D7999>
points>
changing the parameter settings.
512 points
V0 to V7
16 points
Z0 to Z7
32768
Retained by battery during power failure
points
ER0 to
32768
Usable only when memory cassette is
ER32767
points
mounted
For CJ instructions and CALL
4096 points
instructions
to I5
6 points
to I8
3 points
6 points For HSCS instructions
N0 to N7
8 points For MC instructions
16 bits
-32,768 to +32,767
32 bits
-2,147,483,648 to +2,147,483,647
16 bits
0 to FFFF
32 bits
0 to FFFFFFFF
128
-1.0 x 2
to -1.0 x 2
32 bits
Decimal-point and exponential notations are possible.
Designation by characters enclosed with " "
Up to 32 one-byte characters can be used for a
constant in an instruction.
200 kHz x 8 points
100 kHz (multiply by 1),
100 kHz (multiply by 4)
40 kHz
40 kHz (multiply by 1),
10 kHz (multiply by 4)
4.5 Performance Specifications
-126
-126
,0,1.0 x 2
to 1.0 x 2
→ Refer to Section 11.5.
High-speed input special adapter
(FX
-4HSX-ADP)
3U
1
2
3
4
5
6
128
7
8
9
10
59