6.9

Execute from external

Functionality
In <AUTOMATIC> mode > <PROGRAM MANAGER> operating area, the following
interfaces are available for external execution of programs:
Customer CompactFlash card
RCS connection for external execution via network (only for SINUMERIK 802D sl pro)
Manufacturer's drive
USB FlashDrive
Start in the following start screen of the Program Manager:
Figure 6-13
Use vertical softkey "Ext. execution" to transmit the selected external program to the control
system; to execute this program, press <NC START>.
While the contents of the buffer memory are being processed, the blocks are reloaded
automatically.