Siemens SINUMERIK 802D Programming And Operating Manual page 81

Hide thumbs Also See for SINUMERIK 802D:
Table of Contents

Advertisement

The program control softkeys are displayed (e.g. "Skip block", "Program test").
● "Program test":
● "Dry run feedrate":
● "Conditional stop":
● "Skipping":
● "Single block, fine":
● "ROV effective":
Use this softkey to close the screen.
Use the block search function to go to the desired program location.
Forward block search with calculation
During the block search, the same calculations are carried out as during normal program
operation, but the axes do not move.
Forward block search with calculation to the block end point
During the block search, the same calculations are carried out as during normal program
operation, but the axes do not move.
Block search without calculation
During the block search, no calculation is carried out.
The cursor is placed on the main program block of the interrupt point.
The "Find" softkey provides the functions "Find line", "Find text" etc.
Cylindrical grinding
Programming and Operating Manual, 07/2009, 6FC5398-4CP10-2BA0
If "Program test" is selected, the output of setpoints to axes and spindles is disabled. The
set point display "simulates" the traverse movements.
If you select this softkey, all traversing motions will be performed with the feedrate
setpoint specified via the "Dry run feed" setting data. The dry run feedrate function
replaces the programmed motion commands.
When this function is active, processing of the program is stopped at every block in which
miscellaneous function M01 is programmed.
Program blocks, the block number of which is preceded by a slash, are skipped during
program execution (e.g. "/N100").
If this function is active, the part program blocks are executed as follows: Each block is
decoded separately, and a stop is performed at each block; an exception are only the
thread blocks without dry run feedrate. In such blocks, a stop is only performed at the end
of the current thread block. "Single block, fine" can only be selected in the RESET status.
The feedrate override switch will also act on the rapid traverse override.
Automatic mode
6.1 Automatic mode