Refitting The Scanner Wires - Kyocera KM-2530 Service Manual

Hide thumbs Also See for KM-2530:
Table of Contents

Advertisement

5. Unhook the round terminal of the scanner
wire from the scanner tension spring on the
left side of the scanner unit.
6. Remove the scanner wire.
(2-2) Fitting the scanner wires
Caution:
When fitting the wires, be sure to use those specified below.
Machine front: P/N 2AV1219 (black)
Machine rear: P/N 2AV1220 (gray)
Fitting requires the following tools:
Two frame securing tools (P/N 2AV6808)
Two scanner wire stoppers (P/N 3596811)
Procedure
1. Insert the locating ball on each of the scanner
wires into the hole in the respective scanner
wire drum and wind the scanner wire three
turns inward and four turns outward.
• With the locating ball as the reference point,
wind the shorter end of each of the wires
inward.
2. Secure the scanner wires using the scanner
wire stoppers.
Scanner wire
Three turns inward
Locating ball
Four turns outward
Scanner tension spring
Figure 1-6-32
Scanner wire stoppers
Three turns inward
Scanner wire drum
Figure 1-6-29
2DF
Scanner wire
Four turns outward
1-6-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-3530Km-4030

Table of Contents