Maintenance
item No.
U070
Adjusting the DF magnification
Description
Adjusts the DF original scanning speed.
Purpose
To be executed if the correct magnification is not obtained in the auxiliary scanning direction when the optional
DF is used.
Caution
Before making this adjustment, ensure that the following adjustments have been made in maintenance mode.
U053
U065
Method
Press the start key. The screen for executing is displayed.
Setting
1. Change the setting using the cursor up/down keys.
Description
Original conveying motor speed
Increasing the setting makes the image longer, and decreasing it makes the image shorter.
2. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.
U070
Description
Setting range
Initial setting
–25 to +25
–3
Change in value per step
0.1%