Maintenance
item No.
U264
Setting the display order of the date
Description
Selects year, month and day as the order of that appears on lists, etc.
Purpose
Set according to the user preference.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Press the start key. The screen for selecting an item is displayed.
2. Select the desired order.
Display
YEAR-MONTH-DATE
MONTH-DATE-YEAR
DATE-MONTH-YEAR
Initial setting: "MONTH-DATE-YEAR" (for the inch specifications)
3. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U265
Setting OEM purchaser code
Description
Sets the OEM purchaser code.
Purpose
Sets the code when replacing the main PCB and the like.
Method
Press the start key.
Setting
1. Use the numeric keys or cursor up/down keys to adjust the preset value.
2. Press the start key. The count is set , and the screen for selecting a maintenance item is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item is displayed.
U274
Setting the laser scanner unit type
Description
Sets the type of the laser scanner unit according to the label stuck on the laser scanner unit. Moreover,
changes output power of the laser scanner unit.
Purpose
To set the type when the laser scanner unit control is changed. Also if reproducibility of half tone is not proper,
this mode is used to increase the output power of the laser scanner unit to increase the density.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the item to be set. The selected item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
Display
ADJUST DATA
LASER POWER
The setting of LASER POWER is changed into 1 from 0, the output power of LSU is go up and half-tone is
come to come out darkly.
3.Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item is displayed.
Setting
Year/Month/Day
Month/Day/Year
Day/Month/Year
"DATE-MONTH-YEAR" (for the metric specifications)
Description
Type of the laser scanner unit
Laser scanner unit output power
Description
Setting range
0 to 3
0 to 1
2DF
Initial setting
2
0