Kyocera KM-2530 Service Manual page 205

Hide thumbs Also See for KM-2530:
Table of Contents

Advertisement

2DF
Problem
(4)
The eject motor
does not operate.
(5)
The upper lift motor
does not operate
(C1010).
(6)
The lower lift motor
does not operate
(C1020).
(7)
The scanner motor
does not operate.
(8)
Cooling fan motor 1
does not operate.
(9)
Cooling fan motor 2
does not operate.
(10)
Cooling fan motor 3
does not operate.
(11)
Cooling fan motor 4
does not operate.
1-5-52
Causes
Defective main PCB.
Broken upper lift motor
coil.
Poor contact in the upper
lift motor connector termi-
nals.
Defective main PCB.
Broken lower lift motor
coil.
Poor contact in the lower
lift motor connector termi-
nals.
Defective main PCB.
Broken scanner motor coil.
Poor contact in the scan-
ner motor connector termi-
nals.
Broken cooling fan motor 1
coil.
Poor contact in the cooling
fan motor 1 connector ter-
minals.
Broken cooling fan motor 2
coil.
Poor contact in the cooling
fan motor 2 connector ter-
minals.
Broken cooling fan motor 3
coil.
Poor contact in the cooling
fan motor 3 connector ter-
minals.
Broken cooling fan motor 4
coil.
Poor contact in the cooling
fan motor 4 connector ter-
minals.
Check procedures/corrective measures
Run maintenance item U030 and check if CN16-B11, CN16-
B12, CN16-B13 and CN16-B14 on the main PCB go low. If not,
replace the main PCB.
Check for continuity across the coil. If none, replace the upper
lift motor.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check if 24 V DC is output across CN13-A17 on the main PCB
right after the upper drawer is installed. If not, replace the main
PCB.
Check for continuity across the coil. If none, replace the lower lift
motor.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check if 24 V DC is output across CN13-B7 on the main PCB
right after the lower drawer is installed. If not, replace the main
PCB.
Check for continuity across the coil. If none, replace the scanner
motor.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 1.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 2.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 3.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 4.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, repair or replace the cable.