Maintenance
item No.
U063
Adjusting the shading position
Description
Changes the shading position.
Purpose
Used when white lines continue to appear longitudinally on the image after the shading plate is cleaned. This is
due to flaws or stains inside the shading plate. To prevent this problem, the shading position should be changed
so that shading is possible without being affected by the flaws or stains.
Method
1. Press the start key. The screen for adjustment is displayed.
2. Change the setting using the cursor up/down keys.
Description
Shading position
Increasing the setting moves the shading position toward the machine right, and decreasing it moves the
position toward the machine left.
3. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy mode.
Completion
Press the stop/clear key at the screen for adjustment. The screen for selecting a maintenance item No. is
displayed.
U065
Adjusting the scanner magnification
Adjustment
See pages 1-6-27 and 28.
U066
Adjusting the leading edge registration for scanning an original on the contact glass
Adjustment
See page 1-6-29.
U067
Adjusting the center line for scanning an original on the contact glass
Adjustment
See page 1-6-30.
U068
Adjusting the scanning position for originals from the DF
Description
Adjusts the position for scanning originals from the DF.
Purpose
Used when there is a regular error between the leading edges of the original and the copy image when the DF
is used.
Method
Press the start key. The screen for executing is displayed.
Setting
1. Change the setting using the cursor up/down keys.
Description
Scanning position
Increasing the setting moves the image backward, and decreasing it moves the image forward.
2. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
1-4-14
Description
Setting range
Initial setting
–5 to +5
0
Setting range
Initial setting
–2 to +3
0
Change in value per step
0.17 mm
Change in value per step
0.254 mm