1-3-13 Installing the duplex unit (option)

Preparation
1. Open the conveying cover.
2. Remove the screw from the front and rear
struts respectively to remove the struts and
remove the conveying cover in the horizontal
direction.
Conveying cover
3. Insert the nut plates into the paper conveying
bases.
4. Raise the release lever of the conveying unit,
open the conveying unit a little, and hang the
hook sections in the front and rear of the
duplex unit on the shaft of the conveying unit.
5. Secure the duplex unit using the four M3 × 10
bronze binding screws.
1-3-48
Screws
Struts
Duplex unit
M3 × 10
bronze binding screws
M3 × 10
bronze binding screws
Conveying cover
Figure 1-3-102
Paper conveying base
Nut plates
Figure 1-3-103
Hook
Figure 1-3-104
Paper
conveying base
Shaft
Conveying unit
Release lever