Maintenance
item No.
U251
Checking/clearing the maintenance count
Description
Displays, clears and changes the maintenance count.
Purpose
To check the maintenance count. Also to clear the count during maintenance service.
Method
Press the start key. The maintenance count is displayed.
Clearing
1. Press the reset key.
2. Press the start key. The count is cleared, and the screen for selecting a maintenance item No. is displayed.
Setting
1. Enter a six-digit count using the numeric keys.
2. Press the start key. The count is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The screen for selecting a
maintenance item No. is displayed.
U252
Setting the destination
Description
Switches the operations and screens of the machine according to the destination.
Purpose
To be executed after replacing the backup RAM on the main PCB or initializing the backup RAM by running
maintenance item U020, in order to return the setting to the value before replacement or initialization.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the destination. The selected item is displayed in reverse.
Display
JAPAN METRIC
INCH
EUROPE METRIC
ASIA PACIFIC
2. Press the start key. The setting is set, and the machine automatically returns to the same status as when
the power is turned on.
Completion
To exit this maintenance item without changing the current count, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
Supplement
The specified initial settings are provided according to the destinations in the maintenance items below. To
change the initial settings in those items, be sure to run maintenance item U021 after changing the destination.
• Initial setting according to the destinations
Maintenance Title
item No.
253
255
Description
Metric (Japan) specifications
Inch (North America) specifications
Metric (Europe) specifications
Metric (Asia Pacific) specifications
Switching between double and single counts
Setting auto clear time
Description
Japan Inch
Single Double Double
120 s
Europe Metric,
Asia Pacific
90 s
90 s