Secure a shelf bracket to the interior vertical rails using four (4) Phillips panhead screws with split
lock and flat washers.
Repeat
step 6
7.
8.
Continue to

Attaching the mounting hardware to the director

Use these steps to secure the mounting hardware to the director.
NOTE:
All mounting brackets are attached to the director using 10/32 x 3/8-inch flathead
countersunk Phillips screws.
1.
Locate the two front mounting brackets in the shipping carton.
2.
Secure the front mounting brackets on either side of the director
mounting bracket, use three (3) screws.
Figure 12
Securing the front mounting brackets to the Director 2/140
3.
Locate the two rear mounting plates in the shipping carton.
4.
Secure the two rear mounting plates to each side of the director
three (3) screws.

Inserting cage nuts in the rack

Before placing the director into the rack, insert the cage nuts into the appropriate locations along
the exterior vertical rack rails. Read the following sections for instructions on inserting front and rear
cage nuts in the rack.

Inserting the front cage nuts in the rack

Use these steps to insert the six (6) supplied cage nuts in the rack's front rails.
36
Installing and configuring the director
for each of the three remaining interior vertical rails.
to secure the second shelf bracket on the opposite side of the rack.
"Attaching the mounting hardware to the director" on page
36.
(Figure
12). For each front
(Figure
12). For each plate, use