Install the director on a desktop

To install the director on a desktop:
1.
Position the director on a table or desktop as directed by the customer.
CAUTION:
Four person lift
carry the director with fewer than four people. Failure to observe this CAUTION may result in injury
to personnel or damage to the director.
2.
Verify all field-replaceable units (FRUs), including logic cards, fans, and power supplies are
installed as ordered.
Connect the U.S. or country-specific (optional) AC power cords to the right (PS0) and left (PS1)
3.
receptacles at the rear of the director
Figure 8
AC power connections (director)
WARNING!
electric shock when connecting the director to primary facility power, use only the supplied power
cord(s), and ensure the facility power receptacle is the correct type, supplies the required voltage,
and is properly grounded.
NOTE:
The director does not have a power switch. Therefore the director powers on when its
power cords are connected to facility power.
30
Installing and configuring the director
the director weighs approximately 167 lbs. Do not attempt to lift or
An HP-supplied power cord is provided for each director power supply. To prevent
(Figure
8).