Parameter
Keypad and
structure
8.10

Enable mode select

Coding
Bit
SP
Range
0 to 2
Default
0
Update rate
Background read
As default (Pr 8.10 = 0) the drive is in the inhibit mode when the enable is inactive. Setting this parameter to one causes the enable to behave as an
Et trip input. When the input becomes inactive an Et trip is initiated. This does not affect Pr 10.32 (Et trip parameter), therefore an Et trip can be
initiated in this mode either by making the enable inactive or setting Pr 10.32 to one.
When this is two, a 0 to 1 change on the terminal will cause a reset.
8.11
T24 digital I/O 1 invert
8.12
T25 digital I/O 2 invert
8.13
T26 digital I/O 3 invert
8.14
T27 digital input 4 invert
8.15
T28 digital input 5 invert
8.16

T29 digital input 6 invert

8.17
T51, T52, T53 relay invert
Bit
SP
Coding
1
Default
Pr 8.11 to Pr 8.17 = OFF (0)
Update rate
4 ms read
OFF (0) = Non-inverted
On (1) = Inverted
8.20

Digital I/O read word

Bit
SP
Coding
Range
0 to 4095
Update rate
Background write
This word is used to determine the status of the digital I/O by reading one parameter. The bits in this word reflect the state of Pr 8.01 = {in05, 0.85} to
Pr 8.07, 8.09, and Pr 8.40 to Pr 8.42.
Bit
Digital I/O
0
T24 input / output 1
1
T25 input / output 2
2
T26 input / output 3
3
T27 input 4
4
T28 input 5
5
T29 input 6
6
Relay 1
7
8
Enable
9
Relay 2
10
Start button
11
Forward / Reverse button
Mentor MP Advanced User Guide
Issue Number: 4
format
Parameter description
FI
DE Txt VM DP
ND
FI
DE Txt VM DP
ND
FI
DE Txt VM DP
ND
1
www.onxcontrol.com
Advanced parameter
descriptions
RA NC NV
PT
US RW BU
1
1
RA NC NV PT US
RW
1
1
RA NC NV
PT
US RW BU
1
1
Serial comms
Performance
protocol
PS
BU PS
PS
1
Menu 8