Menu 7 Logic Diagram - Emerson Mentor MP Advanced User's Manual

High performance dc drive 25a to 7400a, 480v to 690v
Hide thumbs Also See for Mentor MP:
Table of Contents

Advertisement

Parameter
Keypad and
structure
Figure 5-23 Menu 7 logic diagram
Analog input 1
A/D
Analog input 2
A/D
Analog input 3
A/D
Analog output 1
source parameter
Any variable
parameter
??.??
3.02
Speed
??.??
feedback
Any
variable
parameter
Current
??.??
magnitude
4.01
??.??
Mentor MP Advanced User Guide
Issue Number: 4
format
Parameter description
Analog
input 1
7.01
Analog input 2
Analog
current loop loss
input 2
7.28
7.02
7.11
Analog input 2
mode selector
Analog input 3
Analog
current loop loss
input 3
7.29
7.03
7.15
Analog input 3
mode selector
7.19
Analog output 1
7.20
7.21
Analog
Analog
output 1
output 1
scaling
mode
selector
Analog output 2
source parameter
7.22
Analog output 2
7.24
7.23
Analog
Analog
output 2
output 2
scaling
mode
selector
www.onxcontrol.com
Advanced parameter
descriptions
Analog input
1 offset
7.30
+
+
7.08
Analog
x(-1)
input 1
scaling
Analog input
2 offset
7.31
+
+
7.12
Analog
input 2
x(-1)
scaling
Analog input
3 offset
7.31
7.32
+
+
7.16
Analog
x(-1)
input 3
scaling
The parameters are all shown at their default settings
Serial comms
Performance
protocol
Analog input 1
destination
Any
paramete r
unprotected
7.10
variable
parameter
??.??
??.??
Analog input 1
7.09
invert
Analog input 2
destination
parameter
Any
7.14
unprotected
variable
parameter
??.??
??.??
Analog input 2
7.13
invert
Analog input 3
destination
parameter
Any
7.18
unprotected
variable
parameter
??.??
??.??
7.17
Analog input
3 invert
Key
Input
Read-write (RW)
0.XX
terminals
parameter
Read-only (RO)
Output
0.XX
parameter
terminals
Menu 7
Analog
ref. 1
1.36
Analog
ref. 2
1.37
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents