Flux Present Threshold; Positive Torque Proving Only; External Brake Released Indicator; Brake Release Action Source - Emerson Mentor MP Advanced User's Manual

High performance dc drive 25a to 7400a, 480v to 690v
Hide thumbs Also See for Mentor MP:
Table of Contents

Advertisement

Parameter
Menu 12
structure
12.52

Flux present threshold

Coding
Bit
SP
Range
0 to 100 %
Default
80 %
Update rate
Background read
This parameter should be set to the level of flux required before the torque proving latch can be set.
12.53

Positive Torque proving only

Coding
Bit
SP
1
Default
0
Update rate
Background read
When this parameter is set to 1, the torque present signal is only given when the armature current is above the threshold in the positive direction.

External brake released indicator

12.54
Coding
Bit
SP
1
Default
0
Update rate
Background read
This parameter is provided for the case where users wish to have positive feedback that the brake is released. This could be done using a brake
release limit switch, or an auxiliary contact on the brake contactor. A digital input needs to be routed to this parameter to monitor the brake state and
Pr 12.55 needs to be set to enable this feature.
12.55

Brake release action source

Coding
Bit
SP
1
Default
0
Update rate
Background read
By default, the brake release action defined by Pr 12.49 is triggered by the brake release logic (Pr 12.40). When this parameter is set to 1, the brake
release action is triggered by an external feedback (Pr 12.54).
170
Keypad and
FI
DE
Txt VM DP
ND RA
FI
DE
Txt VM DP
ND RA
FI
DE
Txt VM DP
ND RA
FI
DE
Txt VM DP
ND RA
www.onxcontrol.com
Advanced parameter
format
descriptions
Parameter description
NC
NV
PT
US RW BU
1
1
1
NC
NV
PT
US RW BU
1
1
NC
NV
PT
US RW BU
1
1
NC
NV
PT
US RW BU
1
1
Serial comms
Performance
protocol
PS
PS
PS
PS
Mentor MP Advanced User Guide
Issue Number: 4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents