Input/Output And Drive Enable Wiring

E Series Drives are equipped with five optically isolated input lines (one
dedicated to a drive enable function) and three optically isolated output lines.
They are designed to operate from a +10 to 30 VDC source. All inputs and
outputs are configured as sourcing. You are responsible for choosing a load that
will limit each output current to less than 200 mA.
vi r
1 0 - 3 0
I N P U T
1 - - V F
L6
Single Point
PE Ground
Figure 24 I n p u t / O u t p u t Sourcing Wiring Diagram
The 1/0 connector is a ten pin removable terminal block. #18 to 24 AWG
stranded wire is recommended.
2.Tik
10 to 30 VDC
OUTPUT]
EN D r i v e J
A h i g h s p e e d d i o d e ( s u c h a s a 1 N 4 0 0 0 )
is r e q u i r e d f o r i n d u c t i v e l o a d s s u c h a s
a r e l a y , s o l e n o i d o r c o n t a c t o r .
Installation
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

En-204En-208En-214

Table of Contents