Dn Fab Master Send Block; Dn Host Mode; Dn Macid - Emerson Control Techniques Epsilon Ei Reference Manual

Table of Contents

Advertisement

Epsilon Ei DeviceNet Drive Reference Manual

DN FAB Master Send Block

Ei-DN
Range
Units
The DN FAB Master Send Block displays the polled data being transferred from the master to the
drive via the Master Send fixed assembly block (FAB).

DN Host Mode

Ei-DN
Range
Units
0,1
Enabling the "Host Mode" gives the host (DeviceNet Master) exclusive control of the following
Input functions:
Index Select and Index Initiate
Jog +, Jog -, Jog Fast
Home Initiate
Define Home
Brake Control and Release
All other functions will be logically OR'ed with inputs and Modbus 3 when in Host mode.
Host mode is useful when access to the hardwire I/O needs to be switched from "DeviceNet only"
to "DeviceNet I/O or Hardware I/O."

DN MacID

Ei-DN
Range
Units
0-63
The DN MacID is the node address of the Ei-DN on the DeviceNet network. The range of this
number is 0-63.
26
Default
Type
DN Type
US16
UINT
Word
Modbus Address
0
34007
1
34008
2
34009
3
34010
Default
Type
DN Type
ENM
Word
Default
Type
DN Type
US16
UINT
Get other manuals https://www.bkmanuals.com
Modbus Address: 34007-34010
Group
NVM
Res.
No
Modbus Address: 44003
Group
NVM
Res.
Yes
Modbus Address: 44001
Group
NVM
Res.
Yes
Access
RO
Access
RW
Access
RW

Advertisement

Table of Contents
loading