Parameter
Keypad and
structure
10.35

Auto-reset delay

Bit
SP
Coding
Range
0.0 to 25.0 s
Default
1.0
Update rate
Background read
If Pr 10.34 is set to zero then no auto reset attempts are made. Any other value will cause the drive to automatically reset following a trip for the
number of times programmed. Pr 10.35 defines the time between the trip and the auto reset. The reset count is only incremented when the trip is the
same as the previous trip, otherwise it is reset to 0. When the reset count reaches the programmed value, any further trip of the same value will not
cause an auto-reset. If there has been no trip for 5 minutes then the reset count is cleared. Auto reset will not occur on Et, EEF or HFxx trips. When a
manual reset occurs the auto reset counter is reset to zero.
10.36

Hold drive OK until last attempt

Bit
SP
Coding
1
Default
0
Update rate
Background read
If this parameter is 0 then Pr 10.01 (Drive OK is cleared every time the drive trips regardless of any auto-reset that may occur. When this parameter is
set the 'Drive OK' indication is not cleared on a trip if an auto-reset is going to occur.
10.38

User trip

Bit
SP
Coding
Range
0 to 255
Default
0
Update rate
Background read
When a value other than zero is written to the user trip parameter the actions described in the following table are performed. The drive immediately
writes the value back to zero. If the value is not included in the table a trip is initiated with the same trip number as the value provided the drive is not
already tripped.
Action
Values written to 10.38
1
31
200
No action
205
210
217-245
Drive reset
100
Clear trip and trip time logs 255
10.40

Status word

Bit
SP
Coding
Range
0 to 32,767
Update rate
Background write
The bits in this parameter correspond to the status bits in menu 10 as follows:
15
14
13
Not used
Not used
Pr 10.14
7
6
5
Pr 10.08
Pr 10.07
Pr 10.06
Mentor MP Advanced User Guide
Issue Number: 4
format
Parameter description
FI
DE Txt VM DP
ND
1
FI
DE Txt VM DP
ND
FI
DE Txt VM DP
ND
Trip code
UV
EEF
SL1.HF
SL2.HF
SL3.HF
HFx
FI
DE Txt VM DP
ND
1
12
11
Pr 10.13
Not used
4
3
Pr 10.05
Pr 10.04
www.onxcontrol.com
Advanced parameter
descriptions
RA NC NV
PT
US RW BU
1
RA NC NV
PT
US RW BU
1
RA NC NV
PT
US RW BU
1
RA NC NV
PT
US RW BU
1
1
10
9
8
Not used
Pr 10.10
Pr 10.09
2
1
0
Pr 10.03
Pr 10.02
Pr 10.01
Serial comms
Performance
protocol
PS
1
1
PS
1
PS
1
1
PS
1
Menu 10