Parameter
Keypad and
structure
3.53
Tachometer input mode
{Fb03, 0.73}
Bit
SP
Coding
Range
0 to 2
Default
0 (DC)
Update rate
Background read
The input electronics for the tachometer input can be configured in 3 ways.
Value
Text
0
DC
1
DC Filt
2
AC
3.54
Encoder direction
Bit
SP
Coding
1
Default
0
Update rate
Background read
If the encoder has been incorrectly wired this bit can be used to correct the encoder feedback.
0 - Clockwise
1 - Anti clockwise
3.55
Select estimated speed on feedback loss
Bit
SP
Coding
1
Default
0
Update rate
Background read
When this bit is set the speed feedback source is automatically changed to estimated speed feedback when the selected speed feedback is lost.