Indicates which bridge in a 12 or 24 parallel system has been requested. This has to be sent via digital I/O or field bus.
05.45 05.46
Slave bridge request status
05.47
Coding
Bit
SP
1
Range
Update rate
The bridge status of the other drives in a 12 or 24 parallel system have to be sent, via digital I/O or field bus, to these parameters. When digital I/O is
setup to use Pr 5.45 to Pr 5.47 the software reads and writes to the I/O at 1 ms.
5.48
External flux feedback select
Bit
SP
Coding
1
Default
0
Second motor
Pr 21.38
parameter
Update rate
1 ms read
When this parameter is set, the flux feedback is taken from Pr 5.89. This has been made available where the field flux is provided by an independent
external controller (not FXMP25).
5.52
IR drop
Bit
SP
Coding
+/- ARMATURE_VOLTAGE_MAX Vdc
Range
Update rate
Background write
The value resulting from the application of Pr 5.61 to the filtered current.
5.53
Back emf
Bit
SP
Coding
+/- ARMATURE_VOLTAGE_MAX Vdc
Range
Update rate
Background write
The calculated motor back emf based on armature voltage minus the IR drop (Pr 5.52).
5.54
Flux feedback
Bit
SP
Coding
±150.0 %
Range
Update rate
Background write
Flux feedback after the current to flux converter, see motor saturation breakpoints (Pr 5.29 and Pr 5.30).