Preset Reference Selector Timer; Keypad Control Mode Reference; Precision Reference Coarse; Precision Reference Fine/Precision Reference Update Disable - Emerson Mentor MP Advanced User's Manual

High performance dc drive 25a to 7400a, 480v to 690v
Hide thumbs Also See for Mentor MP:
Table of Contents

Advertisement

Parameter
Keypad and
structure
1.16

Preset reference selector timer

Bit
SP
Coding
Range
0 to 400.0 s
Default
10.0
Update rate
Background read
This parameter defines the time between preset reference changes when Pr 1.15 is set to 9. If Pr 1.48 is set to 1 then the preset counter and timer are
reset and preset 1 will be selected.
1.17

Keypad control mode reference

Bit
SP
Coding
Range
±MAX_SPEED_REF rpm
Default
0.0
Update rate
4 ms read
The drive can be controlled from the keypad if Pr 1.14 {SE05, 0.26} is set to 4. The Stop and Run keys automatically become active (the Reverse key
may be optionally enabled with Pr 6.13). The speed reference is defined by Pr 1.17. This is a read only parameter that can only be adjusted in status
mode by pressing the Up or Down keys. If keypad control mode is selected, then pressing the Up or Down keys in status mode will cause the drive to
automatically display the keypad reference and adjust it in the relevant direction. This can be done whether the drive is disabled or running. If the Up
or Down keys are held the rate of change of keypad reference increases with time. The units used for to display the keypad reference for different
modes are given below.
See also Pr 1.51 on page 33 (Power-up keypad control mode reference).
1.18

Precision reference coarse

Bit
SP
Coding
Range
±MAX_SPEED_REF rpm
Default
0.0
Update rate
Background read
See below.
1.19
Precision reference fine
Bit
SP
Coding
Range
0 - 0.099 rpm
Default
0.000
Update rate
Background read
The speed reference resolution is restricted to 0.1 rpm from normal parameters, but the resolution can be improved by using the precision reference.
Pr 1.18 defines the coarse part of reference (either positive or negative) with a resolution of 0.1 rpm and Pr 1.19 defines the fine part of the reference
(always positive) with a resolution of 0.001 rpm. The final reference is given by Pr 1.18 + Pr 1.19. Therefore Pr 1.19 increases positive references
away from zero, and decreases negative references towards zero.
1.20
Precision reference update disable
Bit
SP
Coding
1
Default
0
Update rate
Background read
When this bit is at 0 the precision reference parameters are read and stored in internal memory. Because the precision reference has to be set in two
parameters, this bit is provided to prevent the drive reading the parameters while the reference is being updated. Instead, the drive uses the value
stored in memory preventing the possibility of data skew.
Mentor MP Advanced User Guide
Issue Number: 4
format
Parameter description
FI
DE
Txt VM DP ND RA NC NV
1
FI
DE
Txt VM DP ND RA NC NV
1
1
FI
DE
Txt VM DP ND RA NC NV
1
1
FI
DE
Txt VM DP ND RA NC NV
3
FI
DE
Txt VM DP ND RA NC NV
www.onxcontrol.com
Advanced parameter
Serial comms
protocol
descriptions
PT
US RW BU
1
1
1
PT
US RW BU
1
1
PT
US RW BU
1
1
PT
US RW BU
1
1
1
PT
US RW BU
1
1
Performance
PS
PS
1
PS
PS
PS
Menu 1
29

Hide quick links:

Advertisement

Table of Contents
loading