GE 469 Instruction Manual page 212

Motor management relay
Hide thumbs Also See for 469:
Table of Contents

Advertisement

6.3 MEMORY MAP
Table 6–2: MEMORY MAP DATA FORMATS (Sheet 9 of 12)
FORMAT
TYPE
DEFINITION
CODE
76
RTD 12 Alarm
77
Open RTD Alarm
78
Short/Low RTD Alarm
79
Undervoltage Alarm
80
Overvoltage Alarm
81
Volt. Frequency Alarm
82
Power Factor Alarm
83
Reactive Power Alarm
84
Underpower Alarm
85
Trip Counter Alarm
86
Starter Failed Alarm
87
Current Demand Alarm
88
kW Demand Alarm
89
kvar Demand Alarm
90
kVA Demand Alarm
91
Broken Rotor Bar
92
Analog I/P 1 Alarm
93
Analog I/P 2 Alarm
94
Analog I/P 3 Alarm
95
Analog I/P 4 Alarm
96
Reverse Power Alarm
97
Incomplete Sequence Alarm
98
Analog Differential 1-2 Alarm
99
Analog Differential 3-4 Alarm
Ø
101
Service Alarm
102
Control Power Lost
6
103
Cont. Power Applied
104
Emergency Rst. Close
105
Emergency Rst. Open
106
Start While Blocked
107
Relay Not Inserted
108
Trip Coil Super.
109
Breaker Failure
110
Welded Contactor
111
Simulation Started
112
Simulation Stopped
Ø
118
Digital Trace Trigger
119
Serial Trace Trigger
120
RTD 1 High Alarm
121
RTD 2 High Alarm
122
RTD 3 High Alarm
123
RTD 4 High Alarm
124
RTD 5 High Alarm
125
RTD 6 High Alarm
126
RTD 7 High Alarm
127
RTD 8 High Alarm
128
RTD 9 High Alarm
129
RTD 10 High Alarm
130
RTD 11 High Alarm
131
RTD 12 High Alarm
132
Overtorque Alarm
6-50
Courtesy of NationalSwitchgear.com
Ø
Ø
469 Motor Management Relay
Table 6–2: MEMORY MAP DATA FORMATS (Sheet 10 of 12)
FORMAT
TYPE
DEFINITION
CODE
133
R1 Relay Forced
134
R2 Relay Forced
135
R3 Relay Forced
136
R4 Relay Forced
137
R5 Relay Forced
138
Force R1 Disabled
139
Force R2 Disabled
140
Force R3 Disabled
141
Force R4 Disabled
142
Force R5 Disabled
143
Motor Started
FC135
Unsigned
MOTOR SPEED
16 bit integer
0
Low Speed (Speed 1)
1
High Speed (Speed 2)
FC136
Unsigned
ORDER CODE
16 bit integer
Bit 0
0 - Code P5 (5A phase CT),
1 - Code P1 (1A phase CT)
Bit 1
0 - Code HI (High Voltage Power Supply),
1 - Code LO (Low Voltage Power Supply)
Bit 2
0 - Code A20 (4-20 mA Analog Outputs),
1 - Code A1 (0-1 mA Analog Outputs)
FC137
Unsigned
CONTROL RELAYS FOR REDUCED
16 bit integer
VOLTAGE STARTING
0
Auxiliary 2
1
Auxiliary 2 & Auxiliary 3
2
Auxiliary 3
FC138
Unsigned
SIMULATION MODE
16 bit integer
0
Off
1
Simulate Pre-Fault
2
Simulate Fault
3
Pre-Fault to Fault
FC139
Unsigned
FORCE OPERATION OF RELAYS
16 bit integer
0
Disabled
1
R1 Trip
2
R2 Auxiliary
3
R3 Auxiliary
4
R4 Alarm
5
R5 Block Start
6
R6 Service
7
All Relays
8
No Relays
FC140
Unsigned
GENERAL STATUS
16 bit integer
bit 0
Relay in Service
bit 1
Active Trip Condition
bit 2
Active Alarm Condition
bit 3
Reserved
bit 4
Reserved
bit 5
Reserved
bit 6
Reserved
bit 7
Reserved
bit 8
Motor Stopped
6 COMMUNICATIONS