Input Devices On/Off (Test Operation) - Mitsubishi Electric MR-J2S-A Instruction Manual

Servo amplifier
Hide thumbs Also See for MR-J2S-A:
Table of Contents

Advertisement

14. COMMUNICATION FUNCTIONS

14.12.6 Input devices ON/OFF (test operation)

Each input signal can be turned on/off for test operation. Turn off the external input signals.
Send command [9] [2], data No. [0] [0] and data.
Command
Data No.
[9][2]
[0][0]
b31
Command of each bit is transmitted to the slave
station as hexadecimal data.
bit
Signal abbreviation
0
SON
1
LSP
2
LSN
3
TL
4
5
PC
6
RES
7
CR
Set data
See below.
bit
Signal abbreviation
8
9
10
11
ST1
12
ST2
13
14
15
14 - 21
WWW.NNC.IR
b1
b0
1: ON
0: OFF
bit
Signal abbreviation
16
17
18
19
20
21
22
23
bit
Signal abbreviation
24
25
26
27
28
29
30
31