15. ABSOLUTE POSITION DETECTION SYSTEM
1
X26
Servo-on
switch
M23
D11 K1
Processing instruction
RDY signal ON judgement
X26
Servo-on
switch
M13
M14
M16
Servo-on
Error
Retry flag
request
flag
set
M13
Servo-on
request
M17
Retry flag
reset request
X24
M14
Error reset
Error flag
switch
Y33
Alarm reset
X25
Emergency stop
switch
X23
Servo alarm
2
(Continued from preceding page)
SET
M13
FROM
H0000
K816
D11
K1
WAND
H0001
D11
M23
PLS
M24
RST
M8
RST
M13
RST
C0
RST
C1
Y30
PLS
M5
PLS
M17
RST
C2
Y33
M14
RST
M8
RST
M13
Y38
(To be continued)
15 - 53
WWW.NNC.IR
1
Servo-on request
7)
Reading A1SD75 1-axis RDY
signal
Masking RDY signal
Current position change
processing instruction
Current position change flag
Resetting ready
Resetting servo-on request
Resetting ABS transmission
counter at servo OFF
Resetting checksum
transmission counter at servo
OFF
Servo-on output
ABS interface start
Setting retry flag
Resetting retry counter
Alarm reset output
Error flag output
Resetting ready
Resetting servo-on request
Servo alarm
2
Servo-on
control
ABS transfer
retry control
Servo alarm
detection,
alarm reset
control