10. TROUBLESHOOTING

10.2 When alarm or warning has occurred

10.2.1 Alarms and warning list

When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or
warning has occurred, refer to section 10.2.2 or 10.2.3 and take the appropriate action. When an alarm
occurs, ALM turns off.
Set "
1" in parameter No. 49 to output the alarm code in ON/OFF status across the corresponding
pin and SG. Warnings (AL.92 to AL.EA) have no alarm codes. Any alarm code is output at occurrence of
the corresponding alarm. In the normal status, the signals available before alarm code setting (CN1B-19:
ZSP, CN1A-18: INP or SA, CN1A-19: RD) are output.
After its cause has been removed, the alarm can be deactivated in any of the methods marked
alarm deactivation column.
(Note 2) Alarm code
Display
CN1B-19
pin
AL.10
0
AL.12
0
AL.13
0
AL.15
0
AL.16
1
AL.17
0
AL.19
0
AL.1A
1
AL.20
1
AL.24
1
AL.25
1
AL.30
0
AL.31
1
AL.32
1
AL.33
0
AL.35
1
AL.37
0
AL.45
0
AL.46
0
AL.50
0
AL.51
0
AL.52
1
AL.8A
0
AL.8E
0
88888
0
AL.92
AL.96
AL.9F
AL.E0
AL.E1
AL.E3
AL.E5
AL.E6
AL.E9
AL.EA
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. 0: off
1: on
POINT
Configure up a circuit which will detect the trouble (ALM) and turn off the
servo-on (SON) at occurrence of an alarm.
CN1A-18
CN1A-19
pin
pin
1
0
Undervoltage
0
0
Memory error 1
0
0
Clock error
0
0
Memory error 2
1
0
Encoder error 1
0
0
Board error
0
0
Memory error 3
1
0
Motor combination error
1
0
Encoder error 2
0
0
Main circuit error
1
0
Absolute position erase
0
1
Regenerative error
0
1
Overspeed
0
0
Overcurrent
0
1
Overvoltage
0
1
Command pulse frequency error
0
0
Parameter error
1
1
Main circuit device overheat
1
1
Servo motor overheat
1
1
Overload 1
1
1
Overload 2
0
1
Error excessive
0
0
Serial communication time-out error
0
0
Serial communication error
0
0
Watchdog
Open battery cable warning
Home position setting warning
Battery warning
Excessive regenerative warning
Overload warning
Absolute position counter warning
ABS time-out warning
Servo emergency stop warning
Main circuit off warning
ABS servo-on warning
WWW.NNC.IR
Name
10 - 6
in the
Alarm deactivation
Press
Alarm
"SET" on
Power
current
reset
OFF ON
alarm
(RES)
screen.
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
Removing the cause of occurrence
deactivates the alarm
automatically.