Model Code Definition - Mitsubishi Electric MR-J2S-A Instruction Manual

Servo amplifier
Hide thumbs Also See for MR-J2S-A:
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION
Function
Return converter
Alarm history clear
Restart after instantaneous
power failure
Command pulse selection
Input signal selection
Torque limit
Speed limit
Status display
External I/O signal display
Output signal (DO)
forced output
Automatic VC offset
Test operation mode
Analog monitor output
MR Configurator
(Servo configuration software)
Alarm code output
Note. P: Position control mode, S: Speed control mode, T: Torque control mode
P/S: Position/speed control change mode, S/T: Speed/torque control change mode, T/P: Torque/position control change mode

1.5 Model code definition

(1) Rating plate
MITSUBISHI
MODEL
POWER :
POWER
INPUT
OUTPUT :
SERIAL :
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
Description
Used when the regenerative option cannot provide enough
regenerative power.
Can be used with the MR-J2S-500A to MR-J2S-22KA.
Alarm history is cleared.
If the input power supply voltage had reduced to cause an
alarm but has returned to normal, the servo motor can be
restarted by merely switching on the start signal.
Command pulse train form can be selected from among four
different types.
Forward rotation start, reverse rotation start, servo-on
(SON) and other input signals can be assigned to any pins.
Servo motor torque can be limited to any value.
Servo motor speed can be limited to any value.
Servo status is shown on the 5-digit, 7-segment LED
display
ON/OFF statuses of external I/O signals are shown on the
display.
Output signal can be forced on/off independently of the
servo status.
Use this function for output signal wiring check, etc.
Voltage is automatically offset to stop the servo motor if it
does not come to a stop at the analog speed command (VC)
or analog speed limit (VLA) of 0V.
JOG operation positioning operation motor-less operation
DO forced output.
Servo status is output in terms of voltage in real time.
Using a personal computer, parameter setting, test
operation, status display, etc. can be performed.
If an alarm has occurred, the corresponding alarm number
is output in 3-bit code.
AC SERVO
AC SERVO
MR-J2S-60A
600W
:
3.2A 3PH 1PH200-230V 50Hz
3PH 1PH200-230V 60Hz
5.5A 1PH 230V 50/60Hz
170V 0-360Hz 3.6A
A5
TC3
AAAAG52
PASSED
WWW.NNC.IR
Model
Capacity
Applicable power supply
Rated output current
Serial number
1 - 7
(Note)
Reference
Control mode
P, S, T
Section 13.1.3
P, S, T
Parameter No. 16
S
Parameter No. 20
P
Parameter No. 21
Parameters
P, S, T
No. 43 to 48
Section 3.4.1 (5)
P, S
Parameter No. 28
Section 3.4.3 (3)
T
Parameter No. 8
to 10,72 to 75
P, S, T
Section 6.2
P, S, T
Section 6.6
P, S, T
Section 6.7
S, T
Section 6.3
P, S, T
Section 6.8
P, S, T
Parameter No. 17
P, S, T
Section 13.1.9
P, S, T
Section 10.2.1