Power-On Sequence - Mitsubishi Electric MR-J2S-A Instruction Manual

Servo amplifier
Hide thumbs Also See for MR-J2S-A:
Table of Contents

Advertisement

3. SIGNALS AND WIRING

3.7.3 Power-on sequence

(1) Power-on procedure
1) Always wire the power supply as shown in above section 3.7.1 using the magnetic contactor with
the main circuit power supply (three-phase 200V: L
100V: L
, L
). Configure up an external sequence to switch off the magnetic contactor as soon as
1
2
an alarm occurs.
2) Switch on the control circuit power supply L
supply or before switching on the main circuit power supply. If the main circuit power supply is
not on, the display shows the corresponding warning. However, by switching on the main circuit
power supply, the warning disappears and the servo amplifier will operate properly.
3) The servo amplifier can accept the servo-on (SON) about 1 to 2s after the main circuit power
supply is switched on. Therefore, when SON is switched on simultaneously with the main circuit
power supply, the base circuit will switch on in about 1 to 2s, and the ready (RD) will switch on
in further about 20ms, making the servo amplifier ready to operate. (Refer to (2) in this section)
4) When the reset (RES) is switched on, the base circuit is shut off and the servo motor shaft
coasts.
(2) Timing chart
Main circuit
ON
Control circuit
OFF
Power supply
ON
Base circuit
OFF
Servo-on
ON
(SON)
OFF
Reset
ON
(RES)
OFF
Ready
ON
(RD)
OFF
No (ON)
Trouble (ALM)
Yes (OFF)
, L
11
Servo-on (SON) accepted
(1 to 2s)
10ms
20ms
10ms
Power-on timing chart
3 - 50
WWW.NNC.IR
, L
, L
, single-phase 230V, single-phase
1
2
3
simultaneously with the main circuit power
21
10ms
60ms
60ms
20ms
10ms
20ms
10ms