Mitsubishi Electric MR-J2S-A Instruction Manual page 129

Servo amplifier
Hide thumbs Also See for MR-J2S-A:
Table of Contents

Advertisement

5. PARAMETERS
Class No. Symbol
1
*OP1
Function selection 1
Used to select the input signal filter, pin CN1B-19 function and
absolute position detection system.
Name and function
Input signal filter
If external input signal causes chattering due to noise,
etc., input filter is used to suppress it.
0: None
1: 1.777[ms]
2: 3.555[ms]
3: 5.333[ms]
CN1B-pin 19's function selection
0: Zero Speed detection (ZSP)
1: Electromagnetic brake interlock (MBR)
CN1B-pin 18's function selection
0: Alarm (ALM)
1: Dynamic brake interlock (DB)
When using the external dynamic brake with 11kW or
more, make dynamic brake interlock (DB) valid.
Selection of absolute position detection system (Refer
to chapter 15)
0: Used in incremental system
1: Used in absolute position detection system
5 - 6
WWW.NNC.IR
Initial
Setting
Control
Unit
value
range
mode
0002
P S T
Refer to
Name
and
function.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents