Advertisement

5. PARAMETERS
Class No. Symbol
60
LPF
Low-pass filter adaptive vibration suppression control
Used to selection the low-pass filter adaptive vibration suppression
control. (Refer to chapter 8)
61
GD2B Ratio of load inertia moment to servo motor inertia moment 2
Used to set the ratio of load inertia moment to servo motor inertia
moment when gain changing is valid.
62
PG2B Position control gain 2 changing ratio
Used to set the ratio of changing the position control gain 2 when
gain changing is valid.
Made valid when auto tuning is invalid.
63
VG2B Speed control gain 2 changing ratio
Used to set the ratio of changing the speed control gain 2 when gain
changing is valid.
Made valid when auto tuning is invalid.
64
VICB
Speed integral compensation changing ratio
Used to set the ratio of changing the speed integral compensation
when gain changing is valid. Made valid when auto tuning is invalid.
Name and function
0
Low-pass filter selection
0: Valid (Automatic adjustment)
1: Invalid
When you choose "valid", the filter of the handwidth
represented by the following expression is set automatically
For 1kW or less
VG2 setting 10
[H
2
(1 GD2 setting 0.1)
For 2kW or more
VG2 setting 5
[H
2
(1 GD2 setting 0.1)
Adaptive vibration suppression control selection
Choosing "valid" or "held" in adaptive vibration
suppression control selection makes the machine
resonance control filter 1 (parameter No. 58) invalid.
0: Invalid
1: Valid
Machine resonance frequency is always detected
and the filter is generated in response to resonance to
suppress machine vibration.
2: Held
The characteristics of the filter generated so far are held,
and detection of machine resonance is stopped.
Adaptive vibration suppression control sensitivity selection
Used to set the sensitivity of machine resonance detection.
0: Normal
1: Large sensitivity
5 - 23
WWW.NNC.IR
Initial
value
0000
]
z
]
z
70
100
100
100
Setting
Control
Unit
range
mode
P S T
Refer to
Name
and
function
column.
0.1
0
P S
times
to
3000
%
10
P
to
200
%
10
P S
to
200
%
50
P S
to
1000