Load Stability Indicator - Lsi (2505H) - JLG G5-18A Operation Manual

Hide thumbs Also See for G5-18A:
Table of Contents

Advertisement

Section 3 - Controls and Indicators

Load Stability Indicator - LSI (2505H)

TIP OVER HAZARD. The LSI considers only longitudinal stability limitations, observe
all operating parameters. Failure to follow operating parameters of the telehandler
could damage the equipment and/or cause tip over.
The LSI (9) provides visual and audible indication of forward stability limitations when
machine is static on firm, level surface.
• Green LED (10) will illuminate when LSI power is on.
• When approaching forward stability limitations LEDs progressively illuminate, green
(11), then orange (12) and finally red (13).
• If the red LED illuminates the warning buzzer also sounds.
The LSI has two modes:
Active Mode (CE & AUS)
• As the telehandler reaches forward stability limitations and the red LED (13)
illuminates, the automatic function cut-out is activated. All boom functions are
disabled except for boom retract (CE & AUS) and boom lift (CE). Retract boom to
re-enable functions.
• In some instances the LSI system may slow down or stop boom functions if
operated close to forward stability limitations. When LEDs begin to flash, certain
functions can not be operated. Retract boom and/or return the joystick to neutral
position for a short period to allow system to reset and LEDs to stop flashing
before proceeding with operation.
3-8
WARNING
9
15
11
13
12
14
10
OAL3021
31200743

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2505h

Table of Contents