You can set the quality and resolution for the captured picture.
Upload JPEG Image to Center: Check the checkbox to upload the captured
image to the surveillance center when a VCA alarm occurs.
Picture Quality: High, Medium and Low are selectable.
Picture Resolution: 384*288, CIF, 4CIF, 720P, and 1080P are selectable.
Note:
Selectable picture resolution options vary according to different
camera models.

5.8.5 Behavior Analysis

Purpose:
The behavior analysis detects a series of suspicious behavior, and certain linkage
methods will be enabled if the alarm is triggered. Refer to the following steps to
configure behavior analysis settings.
Steps:
1. Configure the display information and snapshot settings from the VCA Info. page.
2. Set the Camera Calibration
Perform the following steps to three-dimensionally measure and quantize the
image from the camera, and then calculate the size of every target. The VCA
detection will be more accurate if the camera calibration is configured.
Steps:
1) Enter the Camera Calibration setting interface:
Configuration > VCA Configuration > Camera Calibration
2) Check the checkbox of Camera Calibration to enable this function.
3) Select the calibration mode as Input Basic Data or Draw on Live View Video.
Input Basic Data: Input the mounting height, viewing angle, and horizon
ratio of the camera manually.
Draw on Live View Video: Click Draw Verification Line (Horizontal) /
(Vertical) to draw a horizontal/vertical line in the live view, and input the
actual length in Real Length field. With the drawn reference lines and their
real length, the camera can conclude other objects appear in the live view.