Temperature Measurement - HIKVISION UD02330B User Manual

Thermometric network bullet camera
Table of Contents

Advertisement

Figure 5-46 Configuring Dynamic Fire Source Detection
3. Check the checkbox of Display Fire Source Frame on Stream to display a red
frame around the fire source on stream when fire occurs. (Optional)
4. You can slide the cursor to adjust the sensitivity degree of dynamic fire source
detection from 1to 10. The bigger the number is, the more sensitive the detecting
would be.
5. Check the checkbox to select the linkage method taken for the alarm input. Please
refer to Task 3: Set the Alarm Actions for Motion Detection in Section Motion
Detection. In the field of Other Linkage, you can check the checkbox to enable
the alarm output (The alarm output number varies depending on device ability).
6. Click Save to save the settings.

5.7 Temperature Measurement

Purpose:
When you enable this function, it measures the actual temperature of the spot being
monitored. The device alarms when temperature exceeds the temperature threshold
value.
Before You Start:
Enter Configuration > Advanced Configuration > System > VCA Resource Type
to select Temperature Measurement + Behavior Analysis as VCA Resource Type.
Thermometric Network Bullet Camera User Manual
75

Advertisement

Table of Contents
loading

Table of Contents