Detection Sensitivity [0~4]: Refers to the sensitivity of the camera detects a
target. The higher the value, the easier a target be recognized, and the higher
the misinformation is. The default value of 3 is recommended.
Background Update Rate [0~4]: It refers to the speed of the new scene
replaces the previous scene. The default value of 2 is recommended.
Single Alarm: If single alarm is selected, the target in the configured area
will trigger the alarm for only once. If it is not checked, the same target will
cause the continuous alarm in the same configured area.
Leave Interference Suppression: Check this checkbox to stop the
interference caused by the leaves in the configured area.
Output Type: Select the position of the frame. Target center, bottom center,
and top centers are selectable. E.g.: The target will be in the center of the
frame if target center is selected.
Restore Default: Click to restore the configured parameters to the default.
Restart VCA: Restart the algorithms library of behavior analysis.
● Global Size Filter
Note:
Compared with the size filter under rule, which is aiming at each rule,
the global size filter is aiming at all rules.
Steps:
1) Check the checkbox of Global Size Filter to enable the function.
2) Select the Filter Type as Actual Size or Pixel.
Actual Size: Input the length and width of both the maximum size and
the minimum size. Only the target whose size is between the minimum
value and maximum value will trigger the alarm.
Notes:
Camera calibration has to be configured if you select the filter by
actual size.
The length of the maximum size should be longer than the length of
the minimum size, and so does the width.
Pixel: Click Minimum Size to draw the rectangle of the min. size on the