2. Set the alarm rule: Select a temperature measurement rule from the rule list and
configure the parameters.
 Name: You can customize the rule name.
 Type: Select point, line, or frame as rule type.
 Emissivity: Set the emissivity of your target. Note: The emissivity of each
object is different.
 Distance (m): The straight-line distance between the target and the device.
 Reflective Temperature: If there is any target with high emissivity in the
scene, check the checkbox and set the reflective temperature to correct the
temperature. If no such target exists, uncheck the checkbox.
Figure 5-48 Temperature Measurement Configuration
3. Click
in the list to show the alarm rule interface.
 Alarm Rule: The alarm rule varies according to different types. The rule is to
compare the temperature information of two selected regions. For targets set
by frame, the rules include: Max. Temperature is Higher than, Max.
Temperature is Lower than, Min. Temperature is Higher than, Min.
Thermometric Network Bullet Camera User Manual